PowerGuard
Key Features Based on Usage
The PowerGuard system allows you to adjust the maximum power consumption for locations with limited electrical capacity and enables the connection of the machine to both single-phase and three-phase outlets.
PowerGuard intelligently balances the power distribution between the coffee groups and the steam boiler, preventing overloads and ensuring safe and efficient operation.
C0ffee (W) |
Steam (W) |
Total A |
CE |
|||
---|---|---|---|---|---|---|
1 |
2 |
3 |
||||
BABY T 230V |
1 x 1000 |
1 x 1200 |
10 |
5.5 A |
10 A |
10 A |
BABY T 110V |
1 x 1000 |
2 x 600 |
20 |
9 A |
12 A |
20 A |
PowerGuard on Multi-Group Machines
PowerGuard allows machines with two or three coffee groups to be used in professional environments with high energy demands, as well as in locations with limited electrical capacity, without the need to change internal components. In addition, it helps prevent overloads during peak hours (when used in conjunction with other equipment) or to comply with local regulations that specify maximum energy use.
BARISTA |
COFFEE (W) |
STEAM (W) |
TOTAL AMP 230V 1P |
CE |
|||||
---|---|---|---|---|---|---|---|---|---|
1 |
2 |
3 |
4 |
5 |
6 |
||||
2GR |
2 x 1000 |
2 x 1750 |
24 A |
7.5 A |
15 A |
19.5 A |
24 A |
24 A |
24 A |
3GR |
3 x 1000 |
2 x 1750 |
24 A |
7.5 A |
15 A |
19.5 A |
24 A |
24 A |
24 A |
Power/current table |